Telemedicine for ophthalmic consultation services: use of a portable device and layering information for graders
Journal of Telemedicine and Telecare
Published online on March 01, 2016
Abstract
We compared remote, image-based patient consultations to in-person consultations at emergency department and inpatient hospital settings.
Patients evaluated by the ophthalmic consultation services (gold standard) were imaged over a two-week period. A trained study coordinator took anterior segment photographs (AS) and posterior segment photographs (PS) with a portable camera (PictorPlus, Volk Optical, Cleveland, OH). Ophthalmologists (graders) determined photograph quality, presence of pathology, and their confidence in disease detection. At a separate session, graders reassessed photographs accompanied by a one-sentence summary of demographics and chief complaint (CHx). We computed accuracy and reliability statistics.
We took AS photographs of 24 eyes of 15 patients and PS photographs of 39 eyes of 20 patients. The majority of images were rated as acceptable or excellent in quality (AS: 89–96%; PS: 70–75%). Graders detected AS pathology with 62–81% sensitivity based on photographs, increasing to 87–88% sensitivity with photographs plus CHx. Graders detected PS pathology with 79–86% sensitivity based on a photograph only, increasing to 100% sensitivity with photographs plus CHx.
In this pilot study, there is evidence that portable ophthalmic imaging technologies could enable ophthalmologists to remotely evaluate anterior and posterior segment eye diseases with good sensitivity. The ophthalmologist could detect ocular pathology on photographs more accurately if they were provided brief clinical information.