MetaTOC stay on top of your field, easily

A study of 60 patients with percutaneous trigger finger releases: clinical and ultrasonographic findings

, , , ,

Journal of Hand Surgery (European Volume): Journal of the British Society for Surgery of the Hand & Official Journal of the Federation of European Societies for Surgery of the Hand

Published online on

Abstract

We present the clinical results and ultrasonographic findings of 61 trigger digits treated with percutaneous A1 pulley release. An endoscopic carpal tunnel knife was used for the release in the outpatient department. The mean follow-up period was 3.5 months. A total of 55 digits (90%) had complete relief of their triggering postoperatively. Six digits (10%) had Grade 2 triggering clinically in the early postoperative period.The complications included six cases of insufficient release (10%), scar sensitivity in one patient, short-term hypoaesthesia in three digits (5%), and flexor tendon laceration noted on postoperative ultrasonography in eight digits (13%). No neurovascular damage was noted on the postoperative ultrasonography. Ultrasonograpy provides information about tendon laceration and changes in thickness of the pulleys and confirm A1 pulley release after surgery, but it does not alter clinical decision-making. We believe that pre- and postoperative ultrasonograpy does not need to be included as a routine examination.