Evaluation of the effect of closed system transfer device syringe adaptor connection in the isolator on cytotoxic residue contamination during intravenous administration
Journal of Oncology Pharmacy Practice
Published online on April 23, 2025
Abstract
Journal of Oncology Pharmacy Practice, Ahead of Print.
IntroductionThe European Biosafety Network recommends that cytotoxic drug surface contamination in pharmacies and patient wards not exceed 0.1 ng/cm2. Among other mitigations, closed system transfer devices (CSTDs) are recommended in the US, Europe, and ...
IntroductionThe European Biosafety Network recommends that cytotoxic drug surface contamination in pharmacies and patient wards not exceed 0.1 ng/cm2. Among other mitigations, closed system transfer devices (CSTDs) are recommended in the US, Europe, and ...